Marine Electrical Repair & Troubleshooting

A breaker that keeps tripping. A generator that won't share load. A drive that faults at sea. We trace the cause, fix it and prove the system is back.

Symptoms

What the fault looks like on board

One symptom can have several causes in several places. These are common ones, and where we look first.

  1. 01

    A breaker that trips under load

    Overload, a motor winding breaking down, a loose termination heating up, or a protection setting that no longer suits the load it protects.

  2. 02

    A generator that won't share load

    Governor or AVR settings, a droop mismatch between sets, a faulty current transformer, or the power management system acting on a bad signal.

  3. 03

    A drive that faults

    An overcurrent or earth fault in the motor cable, DC-bus overvoltage when the load decelerates, poor cooling, or parameters lost after a blackout.

  4. 04

    An earth fault alarm that comes and goes

    Water in a deck junction box, a chafed cable, or insulation breaking down in a motor — usually worse with rain, washing or heavy weather.

  5. 05

    A motor that won't start or runs hot

    The supply, the contactor or overload relay, a lost phase, the starter or drive, or the motor itself.

  6. 06

    Alarms and controls that misbehave

    Failing I/O cards, sensors, wiring or power supplies in the automation, or a signal lost between the control system and the plant.

Diagnosis

Finding the cause, not just the symptom

Most of the time saved in fault finding is saved before anyone boards. Alarm and event logs, when the fault happens, what was changed recently and the drawings tell us where to start and what to bring.

On board we measure rather than swap parts: insulation resistance to isolate an earth fault circuit by circuit, current and voltage under the condition that triggers the fault, the protection relay's own records. Once the cause is found we repair it, test the system back into service under load and record what was done, so the next engineer on board knows what happened. If the repair shows the system itself is at the end of its life, we say so and scope it as a retrofit.

Systems

What we troubleshoot and repair

Faults across the plant, from generation to the consumer.

  • Switchboards

    Breakers, protection relays, busbar connections and the switchboard's own control circuits.

  • Generators

    Excitation and AVR faults, protection trips, synchronising and load-sharing problems.

  • Motors and starters

    Motors that will not start, trip, overheat or run rough; contactors, overloads and starters.

  • Drives

    VFD faults, parameter problems and drive-to-motor issues.

  • Automation and control

    Control circuits, I/O, sensors and the signals between the control system and the plant.

  • Distribution and cabling

    Feeders and consumers that lose supply or trip, and damaged, degraded or badly terminated cables.

Attendance

Where we attend

We plan the attendance around the vessel's schedule and tell you honestly when we can be on board.

FAQ

Questions about electrical repair

How quickly can you attend a vessel?
It depends on where the vessel is and when. We tell you honestly when we can be on board, and plan the visit around her port call where we can.
Do you repair generators and motors?
We find and fix the electrical faults on generators and motors on board — protection, excitation, control, connections and load sharing. Where a machine needs a workshop rewind or a mechanical overhaul, we tell you.

Electrical fault on board?

Tell us the vessel, where she is and what is happening. We'll tell you how fast we can help and what we need from you.