Marine Electrical Repair & Troubleshooting
A breaker that keeps tripping. A generator that won't share load. A drive that faults at sea. We trace the cause, fix it and prove the system is back.
What the fault looks like on board
One symptom can have several causes in several places. These are common ones, and where we look first.
- 01
A breaker that trips under load
Overload, a motor winding breaking down, a loose termination heating up, or a protection setting that no longer suits the load it protects.
- 02
A generator that won't share load
Governor or AVR settings, a droop mismatch between sets, a faulty current transformer, or the power management system acting on a bad signal.
- 03
A drive that faults
An overcurrent or earth fault in the motor cable, DC-bus overvoltage when the load decelerates, poor cooling, or parameters lost after a blackout.
- 04
An earth fault alarm that comes and goes
Water in a deck junction box, a chafed cable, or insulation breaking down in a motor — usually worse with rain, washing or heavy weather.
- 05
A motor that won't start or runs hot
The supply, the contactor or overload relay, a lost phase, the starter or drive, or the motor itself.
- 06
Alarms and controls that misbehave
Failing I/O cards, sensors, wiring or power supplies in the automation, or a signal lost between the control system and the plant.
Finding the cause, not just the symptom
Most of the time saved in fault finding is saved before anyone boards. Alarm and event logs, when the fault happens, what was changed recently and the drawings tell us where to start and what to bring.
On board we measure rather than swap parts: insulation resistance to isolate an earth fault circuit by circuit, current and voltage under the condition that triggers the fault, the protection relay's own records. Once the cause is found we repair it, test the system back into service under load and record what was done, so the next engineer on board knows what happened. If the repair shows the system itself is at the end of its life, we say so and scope it as a retrofit.
What we troubleshoot and repair
Faults across the plant, from generation to the consumer.
Switchboards
Breakers, protection relays, busbar connections and the switchboard's own control circuits.
Generators
Excitation and AVR faults, protection trips, synchronising and load-sharing problems.
Motors and starters
Motors that will not start, trip, overheat or run rough; contactors, overloads and starters.
Drives
VFD faults, parameter problems and drive-to-motor issues.
Automation and control
Control circuits, I/O, sensors and the signals between the control system and the plant.
Distribution and cabling
Feeders and consumers that lose supply or trip, and damaged, degraded or badly terminated cables.
Where we attend
We plan the attendance around the vessel's schedule and tell you honestly when we can be on board.
Related services
- Retrofit & ModernizationShip electrical retrofits: obsolete drives and switchboard parts replaced, distribution and controls modernised, shore power integrated into the existing plant.
- Installation & OutfittingElectrical installation on vessels in service: new equipment, cabling and transits, switchboard connections, motors, drives and controls, then commissioning.
- Marine Electrical ServicesMarine electrical engineering, installation, retrofit, repair and shore power for vessels in service — in shipyards, ports, on board and offshore.
Questions about electrical repair
- How quickly can you attend a vessel?
- It depends on where the vessel is and when. We tell you honestly when we can be on board, and plan the visit around her port call where we can.
- Do you repair generators and motors?
- We find and fix the electrical faults on generators and motors on board — protection, excitation, control, connections and load sharing. Where a machine needs a workshop rewind or a mechanical overhaul, we tell you.